概述:
ZW32-12(G)型號(hao)野外直(zhi)(zhi)(zhi)流(liu)高壓真空度隔(ge)離(li)(li)打開(kai)(低于(yu)(yu)簡(jian)稱英(ying)文“隔(ge)離(li)(li)打開(kai)”)是額定(ding)容(rong)量(liang)工(gong)作電(dian)(dian)(dian)壓12kV、三相(xiang)電(dian)(dian)(dian)機(ji)互動50Hz的(de)野外供(gong)(gong)電(dian)(dian)(dian)裝置(zhi)打開(kai)主(zhu)設(she)備。隔(ge)離(li)(li)打開(kai)核(he)心(xin)適(shi)用(yong)于(yu)(yu)開(kai)斷、關合供(gong)(gong)用(yong)電(dian)(dian)(dian)錢路中(zhong)(zhong)的(de)斷路直(zhi)(zhi)(zhi)流(liu)電(dian)(dian)(dian)量(liang)直(zhi)(zhi)(zhi)流(liu)電(dian)(dian)(dian)量(liang)、電(dian)(dian)(dian)機(ji)負載直(zhi)(zhi)(zhi)流(liu)電(dian)(dian)(dian)量(liang)及斷路直(zhi)(zhi)(zhi)流(liu)電(dian)(dian)(dian)量(liang),擁有電(dian)(dian)(dian)機(ji)負載及斷路保護措施職(zhi)(zhi)能,無(wu)法掌控(kong)和檢測的(de)特殊要求,還(huan)可(ke)運行(xing)天邊掌控(kong)和侵入(ru)職(zhi)(zhi)能,比較(jiao)廣泛應適(shi)用(yong)于(yu)(yu)換流(liu)站站、工(gong)礦區工(gong)廠供(gong)(gong)電(dian)(dian)(dian)裝置(zhi)設(she)定(ding)系(xi)統中(zhong)(zhong)做掌控(kong)和運行(xing)之者,十分符合需多次(ci)運行(xing)場合。
低壓斷路器滿(man)足GB1984-2003、DL/T 402-2007和IEC60056等高技術標淮(huai)。
結構特點:
總體設計成(cheng)分為三相電源核心式(shi)自(zi)吸(xi)式(shi)成(cheng)分;
分為封閑型(xing)組成部分,密封帶耐腐蝕(shi)性好,還具有良好的(de)的(de)防(fang)水和防(fang)凝耐腐蝕(shi)性,常用做高溫和性天(tian)氣潮(chao)濕地(di)區劃(hua)分的(de)使用;
采取真(zhen)空(kong)度(du)滅弧,隔熱可信;
開斷(duan)、關(guan)合特性可靠性,無然燒和(he)爆管危害;
體型大小小、權重(zhong)輕(qing),免(mian)檢(jian)修,操作生命長;
分、臺閘(zha)運行(xing)既(ji)可(ke)(ke)人(ren)工操(cao)作,也可(ke)(ke)電動三輪,還可(ke)(ke)操(cao)控;
操動(dong)因構封嚴于電(dian)面板開(kai)關(guan)(guan)柜體最(zui)下面,可以(yi)有效杜絕電(dian)面板開(kai)關(guan)(guan)因持久(jiu)存在(zai)在(zai)戶(hu)外 生態而產生的上(shang)銹;
亢奮(fen)部門來設計趣味性(xing),框架(jia)十(shi)分簡單(dan),動性(xing)耐用,密度小,部門年限(xian)會達(da)10000次。
型號含義:
主要技術參數:
序號順序 | 名 稱 | 公司的 | 數 據 | |||
1 | 額定的電阻 | kV | 12 | |||
2 | 功率交流電 | A | 630 | 1250 | ||
3 | 額定功率幀率 | Hz | 50 | |||
4 | 額定值(zhi)電絕緣平(ping)均水平(ping) | 1min工頻耐受性輸出功率 | 干試 | 42/48(斷口) | ||
濕試 | 34 | |||||
多次雙回路對地 | 2 | |||||
雷閃沖洗(xi)耐受(shou)力電壓值(谷值) | 75/85(斷口) | |||||
5 | 額定容(rong)量(liang)跳閘關合(he)交(jiao)流電(基線) | kA | 50 | 63 | ||
6 | 穩(wen)定短時(shi)間耐受力直流電 | kA | 20 | 25 | ||
7 | 額定功(gong)率谷值受直(zhi)流電 | kA | 50 | 63 | ||
8 | 特(te)殊(shu)燒壞開(kai)關(guan)電流開(kai)斷數次 | 次 | 30 | |||
9 | 載(zai)荷系數短路等問題長期時期 | s | 4 | |||
10 | 特殊實操的(de)直流(liu)(liu)電壓及輔助的(de)電路開關特殊的(de)直流(liu)(liu)電壓 | V | DC220、AC220 、AC/DC220 | |||
11 | 額定負(fu)載(zai)基本操作按順序 | 分-0.3s-合(he)分-180s-合(he)分 | ||||
12 | 過(guo)電(dian)(dian)流(liu)量值脫扣額(e)定電(dian)(dian)流(liu)量值 | A | 5 | |||
13 | 自動化機械期 | 次 | 10000 | |||
14 | 聲響(xiang)觸(chu)頭準許損傷累計額板(ban)材的厚(hou)度 | mm | 3 | |||
15 | 過(guo)功率脫扣(kou)器載荷(he)系數(shu)功率 | A | 5 | |||
16 | 直流電互調(diao)節(jie)器直流電比 | 200/5 400/5 600/5 | ||||
17 | 觸頭開距 | mm | 9±1 | |||
18 | 觸頭超程 | mm | 2±0.5 | |||
19 | 月均分閘強度 | m/s | 1.2±0.3 | |||
20 | 人均重合閘速度快 | m/s | 0.6±0.2 | |||
21 | 分閘時間段 | ms | ≤40 | |||
22 | 分閘期限 | ms | 20~45 | |||
23 | 分閘縱跳周期 | ms | ≤2 | |||
24 | 三相(xiang)電源合、分閘與眾不同(tong)期性(xing) | mm | ≤2 | |||
25 | 380V雙回路電阻器 | μΩ | ≤80 帶要進行隔離≤120 |
外形及安裝尺寸:
233--------m.jianil.com
200--------m.209091.com
259--------m.9798722.com
295--------m.ntwths.com
441--------m.zhenjiubbs.com