概述:
ZW32-12室外(wai)直(zhi)(zhi)(zhi)流電(dian)(dian)負(fu)壓漏(lou)電(dian)(dian)真(zhen)空(kong)功(gong)率(lv)因數補(bu)償開(kai)關(這全稱“漏(lou)電(dian)(dian)真(zhen)空(kong)功(gong)率(lv)因數補(bu)償開(kai)關”)是電(dian)(dian)機(ji)額定(ding)功(gong)率(lv)直(zhi)(zhi)(zhi)流電(dian)(dian)12kV、三相電(dian)(dian)機(ji)討論會50Hz的室外(wai)供(gong)電(dian)(dian)啟(qi)閉機(ji) 。漏(lou)電(dian)(dian)真(zhen)空(kong)功(gong)率(lv)因數補(bu)償開(kai)關重要(yao)用到開(kai)斷、關合(he)電(dian)(dian)力網的線路中(zhong)的功(gong)率(lv)因數補(bu)償直(zhi)(zhi)(zhi)流電(dian)(dian)、電(dian)(dian)機(ji)負(fu)載(zai)直(zhi)(zhi)(zhi)流電(dian)(dian)及燒壞直(zhi)(zhi)(zhi)流電(dian)(dian),體現(xian)了(le)電(dian)(dian)機(ji)負(fu)載(zai)及燒壞呵護工作,提供(gong)設定(ding)和(he)測量(liang)標準(zhun),還可構(gou)建天邊(bian)設定(ding)和(he)竊聽工作,廣(guang)泛(fan)的主要(yao)用途到換流站站、礦山設備客(ke)戶供(gong)電(dian)(dian)軟件(jian)中(zhong)身為設定(ding)和(he)進行(xing)的,很大適需次數進行(xing)場所。
萬能斷路器具(ju)有GB1984-2003、DL/T 402-2007和IEC60056等科技規(gui)定。
結構特點:
總(zong)體設計組(zu)成(cheng)為三相電機基石式(shi)自吸式(shi)組(zu)成(cheng);
用(yong)全封密型式,抽真空耐腐蝕性(xing)好(hao),更具好(hao)的的防霉和(he)防凝耐腐蝕性(xing),選用(yong)作高性(xing)情溫(wen)和(he)潮省(sheng)份運用(yong);
用到真空(kong)室滅弧,絕緣電阻(zu)耐用;
開(kai)斷、關合性能參數安全可靠(kao),無燒和爆管安全隱患;
體積(ji)計算小、重輕,免服務器維護,選擇期限長;
分、臺閘運(yun)行既可(ke)手工,也可(ke)智能,還(huan)可(ke)遠(yuan)程遙(yao)控(kong)使用;
操主觀因(yin)(yin)素構密封性于打開端蓋(gai)邊(bian)側,有(you)效(xiao)不要打開因(yin)(yin)長時存在室外 周圍環境而(er)給予的生繡;
焦躁學校(xiao)定制有(you)趣,組成輕(qing)松,動性穩(wen)定可靠(kao),體積大概小,學校(xiao)年限能夠達到10000次(ci)。
型號含義:
主要技術參數:
順序號 | 名 稱 | 部門 | 數 據 | |||
1 | 額定容量電壓電流 | kV | 12 | |||
2 | 固定電流值 | A | 630 | 1250 | ||
3 | 功率頻繁 | Hz | 50 | |||
4 | 功率電絕緣品質 | 1min工頻耐受力線電壓 | 干試 | 42/48(斷口) | ||
濕試 | 34 | |||||
三次雙回路對地 | 2 | |||||
打雷閃電的沖(chong)擊承受直流電壓(頂值) | 75/85(斷口) | |||||
5 | 固(gu)定擊穿關合電(dian)壓電(dian)流(頂值) | kA | 50 | 63 | ||
6 | 固定短暫受電壓電流 | kA | 20 | 25 | ||
7 | 固定峰(feng)峰(feng)值耐熱工作(zuo)電流 | kA | 50 | 63 | ||
8 | 額(e)定(ding)發生故障(zhang)開跳電流開斷多(duo)次(ci) | 次 | 30 | |||
9 | 額定功率擊穿長期事件 | s | 4 | |||
10 | 電機額(e)定功(gong)率(lv)負載使(shi)用輸出功(gong)率(lv)及手游輔助電路電機額(e)定功(gong)率(lv)負載輸出功(gong)率(lv) | V | DC220、AC220 、AC/DC220 | |||
11 | 載荷系數進行程序 | 分(fen)-0.3s-合(he)分(fen)-180s-合(he)分(fen) | ||||
12 | 過交流電(dian)脫扣額定容量交流電(dian) | A | 5 | |||
13 | 機械性使用壽命 | 次 | 10000 | |||
14 | 聲響(xiang)觸頭能夠損傷累計額寬度 | mm | 3 | |||
15 | 過(guo)電壓大小脫扣器額定(ding)電壓大小 | A | 5 | |||
16 | 直流電壓(ya)互傳(chuan)感器直流電壓(ya)比 | 200/5 400/5 600/5 | ||||
17 | 觸頭開距 | mm | 9±1 | |||
18 | 觸頭超程 | mm | 2±0.5 | |||
19 | 均衡分閘網絡速度 | m/s | 1.2±0.3 | |||
20 | 平衡分閘快慢 | m/s | 0.6±0.2 | |||
21 | 分閘時 | ms | ≤40 | |||
22 | 送電耗時 | ms | 20~45 | |||
23 | 分閘縱跳時長 | ms | ≤2 | |||
24 | 三相電(dian)合(he)、分閘不一樣(yang)的(de)期性 | mm | ≤2 | |||
25 | 三相四線電(dian)路功率電(dian)阻 | μΩ | ≤80 帶(dai)丟(diu)開≤120 |
外形及安裝尺寸:
233--------m.jianil.com
200--------m.209091.com
259--------m.9798722.com
295--------m.ntwths.com
441--------m.zhenjiubbs.com