概述:
ZW32-12野外進行高(gao)壓(ya)真空室(shi)萬(wan)(wan)能(neng)(neng)(neng)萬(wan)(wan)能(neng)(neng)(neng)高(gao)壓(ya)斷路(lu)器(下面(mian)的(de)縮寫英文“萬(wan)(wan)能(neng)(neng)(neng)萬(wan)(wan)能(neng)(neng)(neng)高(gao)壓(ya)斷路(lu)器”)是固(gu)定輸出功率12kV、380V溝通50Hz的(de)野外供電(dian)(dian)(dian)旋鈕機(ji)(ji)器設(she)備(bei)。萬(wan)(wan)能(neng)(neng)(neng)萬(wan)(wan)能(neng)(neng)(neng)高(gao)壓(ya)斷路(lu)器主(zhu)要(yao)(yao)的(de)用(yong)來開斷、關(guan)合功率層面(mian)中的(de)負(fu)載感(gan)應(ying)(ying)電(dian)(dian)(dian)流(liu)(liu)量量、電(dian)(dian)(dian)機(ji)(ji)負(fu)載感(gan)應(ying)(ying)電(dian)(dian)(dian)流(liu)(liu)量量及串電(dian)(dian)(dian)感(gan)應(ying)(ying)電(dian)(dian)(dian)流(liu)(liu)量量,具備(bei)電(dian)(dian)(dian)機(ji)(ji)負(fu)載及串電(dian)(dian)(dian)護(hu)理性能(neng)(neng)(neng),需(xu)要(yao)(yao)滿(man)足保持和測量方法要(yao)(yao),還可滿(man)足其他保持和監聽手機(ji)(ji)性能(neng)(neng)(neng),范圍(wei)廣用(yong)來變(bian)配發電(dian)(dian)(dian)站、工(gong)業(ye)工(gong)業(ye)企業(ye)供電(dian)(dian)(dian)掌控系統中用(yong)作(zuo)保持和操(cao)(cao)作(zuo)的(de)使用(yong)的(de),越(yue)來越(yue)比較合適需(xu)過頻操(cao)(cao)作(zuo)的(de)使用(yong)辦公場所(suo)。
萬能斷路器符合(he)規格(ge)GB1984-2003、DL/T 402-2007和IEC60056等枝(zhi)術規格(ge)。
結構特點:
總(zong)的格局為三相四線制支撐體(ti)系式濕式格局;
采用了封(feng)閉(bi)性機構(gou),封(feng)閉(bi)特點(dian)好,有良好的的防(fang)霉和防(fang)凝特點(dian),適(shi)合于(yu)高性情溫和濕潮城市(shi)運(yun)行(xing);
所采用(yong)進(jin)口真空滅弧,絕(jue)緣(yuan)層牢靠;
開斷、關合耐熱性靠譜,無一氧化碳燃燒和發生爆炸危險物品;
占(zhan)地小、凈重輕,免檢(jian)修,運(yun)行期限(xian)長;
分(fen)、臺閘實操(cao)既(ji)可(ke)手動式(shi),也可(ke)電動式(shi),還可(ke)遙控操(cao)作;
操因素構抽真(zhen)空(kong)于旋鈕(niu)膽機(ji)機(ji)箱(xiang)下端,可以效防止旋鈕(niu)因長(chang)時(shi)長(chang)期處在室(shi)外 室(shi)內環境而受到的銹跡;
躁(zao)動不安學校(xiao)開發獨特,架構簡(jian)簡(jian)單單,動性耐用,表(biao)面積小,學校(xiao)耐用度大約(yue)10000次(ci)。
型號含義:
主要技術參數:
順序號 | 名 稱 | 院校 | 數 據 | |||
1 | 固定線電壓 | kV | 12 | |||
2 | 額定值交流電 | A | 630 | 1250 | ||
3 | 額定容量速度 | Hz | 50 | |||
4 | 載荷系數電絕緣平行 | 1min工頻耐受力相電(dian)壓(ya) | 干試 | 42/48(斷口) | ||
濕試 | 34 | |||||
三次控制回路對地 | 2 | |||||
沙塵沖擊力(li)受端(duan)電(dian)壓(最高值) | 75/85(斷口) | |||||
5 | 電機額定功(gong)率擊穿關合(he)感(gan)應電流(谷值) | kA | 50 | 63 | ||
6 | 額(e)定容量暫時性耐(nai)受性工作電流 | kA | 20 | 25 | ||
7 | 特殊頂值接受電流值 | kA | 50 | 63 | ||
8 | 功(gong)率發生故障開無電流開斷多次 | 次 | 30 | |||
9 | 額(e)定容量短路(lu)故障定期日子 | s | 4 | |||
10 | 額定(ding)的操作電(dian)流值(zhi)(zhi)及捕助雙(shuang)回路額定(ding)電(dian)流值(zhi)(zhi) | V | DC220、AC220 、AC/DC220 | |||
11 | 額定功率運營順尋 | 分(fen)-0.3s-合分(fen)-180s-合分(fen) | ||||
12 | 過(guo)直(zhi)流電脫(tuo)扣穩(wen)定直(zhi)流電 | A | 5 | |||
13 | 機戒質保期 | 次 | 10000 | |||
14 | 響動觸頭容許損耗當(dang)年度機的薄厚 | mm | 3 | |||
15 | 過(guo)電壓脫扣器額定容量(liang)電壓 | A | 5 | |||
16 | 工作(zuo)電流大(da)小互紅外感(gan)應器工作(zuo)電流大(da)小比 | 200/5 400/5 600/5 | ||||
17 | 觸頭開距 | mm | 9±1 | |||
18 | 觸頭超程 | mm | 2±0.5 | |||
19 | 人均分閘快慢 | m/s | 1.2±0.3 | |||
20 | 人均重合閘極限速度 | m/s | 0.6±0.2 | |||
21 | 分閘時間段 | ms | ≤40 | |||
22 | 重合閘準確時間 | ms | 20~45 | |||
23 | 分閘跳躍時間間隔 | ms | ≤2 | |||
24 | 相電壓合、分閘區別(bie)期性(xing) | mm | ≤2 | |||
25 | 單相雙回路電阻器 | μΩ | ≤80 帶防護隔離≤120 |