概述:
ZW32-12(G)類型室內(nei)超高壓(ya)(ya)渦(wo)流(liu)(liu)空(kong)氣面板(ban)開(kai)(kai)關(guan)(之下(xia)簡稱(cheng)英文“空(kong)氣面板(ban)開(kai)(kai)關(guan)”)是(shi)額定的(de)(de)(de)相電(dian)(dian)(dian)(dian)(dian)壓(ya)(ya)12kV、380V交換(huan)50Hz的(de)(de)(de)室內(nei)供(gong)電(dian)(dian)(dian)(dian)(dian)系(xi)統的(de)(de)(de)面板(ban)開(kai)(kai)關(guan)主(zhu)設備。空(kong)氣面板(ban)開(kai)(kai)關(guan)包括(kuo)適(shi)用開(kai)(kai)斷、關(guan)合電(dian)(dian)(dian)(dian)(dian)力工程路線(xian)圖中的(de)(de)(de)承載感(gan)(gan)應(ying)(ying)電(dian)(dian)(dian)(dian)(dian)壓(ya)(ya)感(gan)(gan)應(ying)(ying)電(dian)(dian)(dian)(dian)(dian)流(liu)(liu)、電(dian)(dian)(dian)(dian)(dian)機負載感(gan)(gan)應(ying)(ying)電(dian)(dian)(dian)(dian)(dian)壓(ya)(ya)感(gan)(gan)應(ying)(ying)電(dian)(dian)(dian)(dian)(dian)流(liu)(liu)及(ji)不(bu)導通感(gan)(gan)應(ying)(ying)電(dian)(dian)(dian)(dian)(dian)壓(ya)(ya)感(gan)(gan)應(ying)(ying)電(dian)(dian)(dian)(dian)(dian)流(liu)(liu),體現了電(dian)(dian)(dian)(dian)(dian)機負載及(ji)不(bu)導通養護(hu)性能,需(xu)求設定和校正想要,還可(ke)構建家(jia)的(de)(de)(de)方向設定和阻(zu)止(zhi)性能,大(da)范圍應(ying)(ying)適(shi)用變電(dian)(dian)(dian)(dian)(dian)器站、礦山機械(xie)公司供(gong)電(dian)(dian)(dian)(dian)(dian)系(xi)統的(de)(de)(de)系(xi)統的(de)(de)(de)中充當設定和進行之者,非常比較(jiao)適(shi)合需(xu)頻頻進行地方。
漏電斷路(lu)器具有(you)GB1984-2003、DL/T 402-2007和IEC60056等方法(fa)規(gui)范標準(zhun)。
結構特點:
總體設計架構(gou)為三相(xiang)電源先導性式干井式架構(gou);
主要采用全封閉式式空間結構,抽(chou)真(zhen)空耐磨(mo)性(xing)方(fang)面好,都具有(you)積極的(de)防自(zi)然(ran)環(huan)境(jing)和防凝(ning)耐磨(mo)性(xing)方(fang)面,支(zhi)持于高無刺激(ji)自(zi)然(ran)環(huan)境(jing)省份采用;
應用(yong)真空箱(xiang)滅弧,絕緣層安全;
開斷、關合特性正(zheng)規,無進行燃燒(shao)和爆破安(an)全;
體積(ji)大概小、體積(ji)輕,免保(bao)養,運用壽命短長(chang);
分(fen)、臺閘操(cao)控既可人工手動(dong)開啟機組,也可直流電動(dong),還(huan)可操(cao)控;
操驅(qu)力構密封性能(neng)于面板開關按鈕殼體下方,有無效以免 面板開關按鈕因長(chang)時出現室外 周(zhou)圍環境而引(yin)發的浮銹;
燥動部(bu)門(men)設計(ji)的(de)新創意,醫(yi)院簡易,動性不(bu)靠譜,重量(liang)小(xiao),部(bu)門(men)生命(ming)周期led光通(tong)量(liang)10000次。
型號含義:
主要技術參數:
序號順序 | 名 稱 | 機關單位 | 數 據 | |||
1 | 額定值電流值 | kV | 12 | |||
2 | 額定的電流值 | A | 630 | 1250 | ||
3 | 固定次數 | Hz | 50 | |||
4 | 額定絕緣電阻質量 | 1min工頻耐受力電(dian)壓值 | 干試 | 42/48(斷口) | ||
濕試 | 34 | |||||
再次電路開關對地 | 2 | |||||
電雷沖擊試(shi)驗耐(nai)受性(xing)端電壓(ya)(頂值) | 75/85(斷口) | |||||
5 | 額定的發生故障關合電流量(頂值) | kA | 50 | 63 | ||
6 | 額定暫(zan)時(shi)性(xing)耐熱直流電 | kA | 20 | 25 | ||
7 | 額定谷值耐熱交流電 | kA | 50 | 63 | ||
8 | 額定(ding)負載跳閘(zha)開(kai)跳閘(zha)流開(kai)斷危害(hai) | 次 | 30 | |||
9 | 功率出現短路(lu)長期日期 | s | 4 | |||
10 | 額定功(gong)率(lv)值操(cao)控直流電流值及(ji)手游輔助控制回路額定功(gong)率(lv)值直流電流值 | V | DC220、AC220 、AC/DC220 | |||
11 | 載荷(he)系數基本操作先后 | 分-0.3s-合(he)分-180s-合(he)分 | ||||
12 | 過(guo)工作(zuo)瞬時電(dian)流(liu)脫(tuo)扣額定功率工作(zuo)瞬時電(dian)流(liu) | A | 5 | |||
13 | 機械廠期限 | 次 | 10000 | |||
14 | 響聲觸頭支持磨損情況(kuang)顯示器寬度 | mm | 3 | |||
15 | 過工作(zuo)直流電脫(tuo)扣器(qi)額定容量(liang)工作(zuo)直流電 | A | 5 | |||
16 | 功率(lv)值互紅(hong)外感應(ying)器功率(lv)值比 | 200/5 400/5 600/5 | ||||
17 | 觸頭開距 | mm | 9±1 | |||
18 | 觸頭超程 | mm | 2±0.5 | |||
19 | 人均分閘速度慢 | m/s | 1.2±0.3 | |||
20 | 最低值分閘的速度 | m/s | 0.6±0.2 | |||
21 | 分閘時間間隔 | ms | ≤40 | |||
22 | 分閘精力 | ms | 20~45 | |||
23 | 分閘縱跳時間段 | ms | ≤2 | |||
24 | 380V合、分閘有(you)所不同(tong)期性 | mm | ≤2 | |||
25 | 單相漏電開關電阻器 | μΩ | ≤80 帶(dai)隔離開≤120 |